1.
Adv Colloid Interface Sci ; 325: 103119, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38447243

RESUMO

Cationic polymers have recently attracted considerable interest as research breakthroughs for various industrial and biomedical applications. They are particularly interesting due to their highly positive charges, acceptable physicochemical properties, and ability to undergo further modifications, making them attractive candidates for biomedical applications. Polyethyleneimines (PEIs), as the most extensively utilized polymers, are one of the valuable and prominent classes of polycations. Owing to their flexible polymeric chains, broad molecular weight (MW) distribution, and repetitive structural units, their customization for functional composites is more feasible. The specific beneficial attributes of PEIs could be introduced by purposeful functionalization or modification, long service life, biocompatibility, and distinct geometry. Therefore, PEIs have significant potential in biotechnology, medicine, and bioscience. In this review, we present the advances in PEI-based nanomaterials, their transfection efficiency, and their toxicity over the past few years. Furthermore, the potential and suitability of PEIs for various applications are highlighted and discussed in detail. This review aims to inspire readers to investigate innovative approaches for the design and development of next-generation PEI-based nanomaterials possessing cutting-edge functionalities and appealing characteristics.


Assuntos
Nanoestruturas , Polietilenoimina , Polietilenoimina/química , Transfecção , Peso Molecular , Polímeros
2.
Micromachines (Basel) ; 11(8)2020 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-32784703

RESUMO

Multiplex polymerase chain reaction (PCR) is an effective tool for simultaneous detection of target genes. Nevertheless, their use has been restricted due to the intrinsic interference between primer pairs. Performing several single PCRs in an array format instead of a multiplex PCR is a simple way to overcome this obstacle. However, there are still major technical challenges in designing a new generation of single PCR microreactors with a small sample volume, rapid thermal cycling, and no evaporation during amplification. We report a simple and robust core-shell bead array for a series of single amplifications. Four core-shell beads with a polymer coating and PCR mixture were synthesized using liquid marble formation and subsequent photo polymerization. Each bead can detect one target gene. We constructed a customised system for thermal cycling of these core-shell beads. Phylogrouping of the E. coli strains was carried out based on the fluorescent signal of the core-shell beads. This platform can be a promising alternative for multiplex nucleic acid analyses due to its simplicity and high throughput. The platform reported here also reduces the cycling time and avoids evaporation as well as contamination of the sample during the amplification process.

3.
Micromachines (Basel) ; 11(3)2020 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-32111025

RESUMO

Over the last three decades, the protocols and procedures of the DNA amplification technique, polymerase chain reaction (PCR), have been optimized and well developed. However, there have been no significant innovations in processes for sample dispersion for PCR that have reduced the amount of single-use or unrecyclable plastic waste produced. To address the issue of plastic waste, this paper reports the synthesis and successful use of a core-shell bead microreactor using photopolymerization of a composite liquid marble as a dispersion process. This platform uses the core-shell bead as a simple and effective sample dispersion medium that significantly reduces plastic waste generated compared to conventional PCR processes. Other improvements over conventional PCR processes of the novel dispersion platform include increasing the throughput capability, enhancing the performance and portability of the thermal cycler, and allowing for the contamination-free storage of samples after thermal cycling.

4.
Lab Chip ; 19(19): 3220-3227, 2019 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-31464317

RESUMO

The polymerase chain reaction (PCR) is a popular and well-established DNA amplification technique. Technological and engineering advancements in the field of microfluidics have fuelled the progress of polymerase chain reaction (PCR) technology in the last three decades. Advances in microfluidics-based PCR technology have significantly reduced the sample volume and thermal cycling time. Further advances led to novel and accurate techniques such as the digital PCR. However, contamination of PCR samples, lack of reusability of the microfluidic PCR platforms, complexity in instrumentation and operation remain as some of the significant drawbacks of conventional microfluidic PCR platforms. Liquid marbles, the recently emerging microfluidic platform, could potentially resolve these drawbacks. This paper reports the first liquid marble based polymerase chain reaction. We demonstrated an experimental setup for the liquid-marble based PCR with a humidity-controlled chamber and an embedded thermal cycler. A concentrated salt solution was used to control the humidity of the PCR chamber which in turn reduces the evaporation rate of the liquid marble. The successful PCR of microbial source tracking markers for faecal contamination was achieved with the system, indicating potential application in water quality monitoring.


Assuntos
Lipídeos/química , Técnicas Analíticas Microfluídicas , Reação em Cadeia da Polimerase , Umidade , Técnicas Analíticas Microfluídicas/instrumentação , Reação em Cadeia da Polimerase/instrumentação
5.
Micromachines (Basel) ; 10(6)2019 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-31248141

RESUMO

Rapid, sensitive, and selective bacterial detection is a hot topic, because the progress in this research area has had a broad range of applications. Novel and innovative strategies for detection and identification of bacterial nucleic acids are important for practical applications. Microfluidics is an emerging technology that only requires small amounts of liquid samples. Microfluidic devices allow for rapid advances in microbiology, enabling access to methods of amplifying nucleic acid molecules and overcoming difficulties faced by conventional. In this review, we summarize the recent progress in microfluidics-based polymerase chain reaction devices for the detection of nucleic acid biomarkers. The paper also discusses the recent development of isothermal nucleic acid amplification and droplet-based microfluidics devices. We discuss recent microfluidic techniques for sample preparation prior to the amplification process.

6.
Micromachines (Basel) ; 10(12)2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31888270

RESUMO

The polymerase chain reaction (PCR) is a robust technique used to make multiple copies of a segment of DNA. However, the available PCR platforms require elaborate and time-consuming operations or costly instruments, hindering their application. Herein, we introduce a sandwiched glass-polydimethylsiloxane (PDMS)-glass microchip containing an array of reactors for the real-time PCR-based detection of multiple waterborne bacteria. The PCR solution was loaded into the array of reactors in a single step utilising capillary filling, eliminating the need for pumps, valves, and liquid handling instruments. Issues of generating and trapping bubbles during the loading chip step were addressed by creating smooth internal reactor surfaces. Triton X-100 was used to enhance PCR compatibility in the chip by minimising the nonspecific adsorption of enzymes. A custom-made real-time PCR instrument was also fabricated to provide thermal cycling to the array chip. The microfluidic device was successfully demonstrated for microbial faecal source tracking (MST) in water.

7.
Lab Chip ; 18(8): 1174-1196, 2018 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-29569666

RESUMO

Cell-free DNA (cfDNA) refers to short fragments of acellular nucleic acids detectable in almost all body fluids, including blood, and is involved in various physiological and pathological phenomena such as immunity, coagulation, aging, and cancer. In cancer patients, a fraction of hematogenous cfDNA originates from tumors, termed circulating tumor DNA (ctDNA), and may carry the same mutations and genetic alterations as those of a primary tumor. Thus, ctDNA potentially provides an opportunity for noninvasive assessment of cancer. Recent advances in ctDNA analysis methods will potentially lead to the development of a liquid biopsy tool for the diagnosis, prognosis, therapy response monitoring, and tracking the rise of new mutant sub-clones in cancer patients. Over the past few decades, cancer-specific mutations in ctDNA have been detected using a variety of untargeted methods such as digital karyotyping, personalized analysis of rearranged ends (PARE), whole-genome sequencing of ctDNA, and targeted approaches such as conventional and digital PCR-based methods and deep sequencing-based technologies. More recently, several chip-based electrochemical sensors have been developed for the analysis of ctDNA in patient samples. This paper aims to comprehensively review the diagnostic, prognostic, and predictive potential of ctDNA as a minimally invasive liquid biopsy for cancer patients. We also present an overview of current advances in the analytical sensitivity and accuracy of ctDNA analysis methods as well as biological and technical challenges, which need to be resolved for the integration of ctDNA analysis into routine clinical practice.


Assuntos
DNA Tumoral Circulante , Dispositivos Lab-On-A-Chip , Biópsia Líquida , Técnicas Analíticas Microfluídicas , Reação em Cadeia da Polimerase , Animais , DNA Tumoral Circulante/sangue , DNA Tumoral Circulante/genética , DNA Tumoral Circulante/isolamento & purificação , Desenho de Equipamento , Humanos , Camundongos
8.
Appl Biochem Biotechnol ; 182(4): 1371-1389, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28194717

RESUMO

An enzyme immobilized on a mesoporous silica nanoparticle can serve as a multiple catalyst for the synthesis of industrially useful chemicals. In this work, MCM-41 nanoparticles were coated with polyethylenimine (MCM-41@PEI) and further modified by chelation of divalent metal ions (M = Co2+, Cu2+, or Pd2+) to produce metal-chelated silica nanoparticles (MCM-41@PEI-M). Thermomyces lanuginosa lipase (TLL) was immobilized onto MCM-41, MCM-41@PEI, and MCM-41@PEI-M by physical adsorption. Maximum immobilization yield and efficiency of 75 ± 3.5 and 65 ± 2.7% were obtained for MCM@PEI-Co, respectively. The highest biocatalytic activity at extremely acidic and basic pH (pH = 3 and 10) values were achieved for MCM-PEI-Co and MCM-PEI-Cu, respectively. Optimum enzymatic activity was observed for MCM-41@PEI-Co at 75 °C, while immobilized lipase on the Co-chelated support retained 70% of its initial activity after 14 days of storage at room temperature. Due to its efficient catalytic performance, MCM-41@PEI-Co was selected for the synthesis of ethyl valerate in the presence of valeric acid and ethanol. The enzymatic esterification yield for immobilized lipase onto MCM-41@PEI-Co was 60 and 53%, respectively, after 24 h of incubation in n-hexane and dimethyl sulfoxide media. Graphical Abstract Divalent metal chelated polyethylenimine coated MCM-41 (MCM-41@PEI-M) was used for immobilization of Thermomyces lanuginosa lipase catalyzing green apple flavor preparation.


Assuntos
Cátions Bivalentes/química , Enzimas Imobilizadas/química , Lipase/química , Nanopartículas/química , Ácidos Pentanoicos/síntese química , Polietilenoimina/química , Dióxido de Silício/química , Adsorção , Técnicas de Química Sintética , Enzimas Imobilizadas/metabolismo , Esterificação , Eurotiales/enzimologia , Concentração de Íons de Hidrogênio , Lipase/metabolismo , Modelos Moleculares , Conformação Proteica , Propriedades de Superfície , Temperatura , Valeratos
SELEÇÃO DE REFERÊNCIAS